Power supply | 110 - 230 VAC ±10% 50/60Hz, (24-30 VDC) |
Rated load current of AC output (resistive load)* | 1 X 10A / 230 VAC |
Rated load current of DC output (resistive load) | 1 X 10A / 30 VDC |
Output circuit power of AC output (resistive load) | 2300 W (230 VAC) |
Output circuit power of DC output (resistive load) | 240 W (24 VDC) |
Power measurement accuracy | P = 5–50 W, +/-3 W P > 50 W, +/-3% |
Digital temperature sensor range (sensor must be ordered separately) |
-50° ~ +125°C |
Operation temperature | -10° ~ +40°C |
Distance | up to 30 m indoors |
Dimensions (WxHxD) | 41.8 x 36.8 x 15.4 mm |
(packaging) | (79x52x22 mm) |
Weight (including packaging) | 28 g (34 g) |
Electricity consumption | 0.4 W |
For installation in boxes | Ø ≥ 60 mm or 2M, depth ≥ 60 mm |
Switching | Relay |
* In the case of loads other than resistive, pay attention to the value of cosφ and if necessary use a load lower than the rated load. Max current for cosφ = 0.4 is 3 A at 250 VAC, 3 A at 24 VDC L/R = 7 ms.
Available configuration parameters (data type is 1 Byte DEC):
To Input I2 you can connect push button for scenes or any kind of binary sensor, like open door-window sensor.
Available configuration parameters (data type is 1 Byte DEC):
TVs, Hi-Fi systems and other home appliances have already integrated automatic turn off functionality, this device also offers this functionality. Automatic turning off function allows energy saving, without doing scenes on Z-Wave controller.
This function, for example also allows automatic re-locking door after defined time.
When Relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the device receive ON command regardless from where it comes (push button, associated device, controller,..).
Available configuration parameters (data type is 2 Byte DEC):
When Relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the device receives OFF command regardless from where it comes (push button, associated device, controller, etc.).
Available configuration parameters (data type is 2 Byte DEC):
Available configuration parameters (data type is 1 Byte DEC):
NOTE: Parameter is the same for turning OFF or ON.
Available configuration parameters (data type is 1 Byte DEC):
Set value means percentage, set value from 0 - 100 = 0 % - 100 %. Available configuration parameters (data type is 1 Byte DEC):
NOTE: If power changed is less than 1 W, the report is not sent (pushed), independent of percentage set.
Set value means time interval (0 – 32535) in seconds, when power report is sent. Available configuration parameters (data type is 2 Byte DEC):
Set value means the type of the device that is connected to the output. The device type can be normally open (NO) or normally close (NC). Available configuration parameters (data type is 1 Byte DEC):
Binary switch and binary sensor I2 and I3 widgets are visible in the UI.
Disabled Endpoint I2 and I3
Widgets are not visible in the UI, only the binary switch widget is.
Enabling I2 & I3 means that Endpoint (I2 & I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Available configuration parameters (data type is 1 Byte DEC):
Endpoint device type selection:
- notification sensor (1 - 6):
GENERIC_TYPE_SENSOR_NOTIFICATION,
SPECIFIC_TYPE_NOTIFICATION_SENSOR
- sensor binary (9):
GENERIC_TYPE_SENSOR_BINARY,
SPECIFIC_TYPE_NOT_USED
NOTE 1: After parameter change, first exclude device (without setting parameters to default value) then wait at least 30 s and then re-include the device!
NOTE 2: When the parameter is set to value 9 the notifications are sent to Home Security.
If the temperature sensor is connected to the device, the temperature sensor widget is shown automatically in UI (user interface).
If the measured temperature with an additional temperature measuring device is different from the one measured by the connected digital temperature sensor, the temperature can be compensated by this parameter.
Available configuration parameters (data type is 2 Byte DEC):
If digital temperature sensor is connected, device reports measured temperature on temperature change defined by this parameter.
Available configuration parameters (data type is 1 Byte DEC):
Available configuration parameters (data type is 1 Byte DEC):
To Input I2 you can connect push button for scenes or any kind of binary sensor, like open door-window sensor.
Available configuration parameters (data type is 1 Byte DEC):
TVs, Hi-Fi systems and other home appliances have already integrated automatic turn off functionality, this device also offers this functionality. Automatic turning off function allows energy saving, without doing scenes on Z-Wave controller.
This function, for example also allows automatic re-locking door after defined time.
When Relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the device receive ON command regardless from where it comes (push button, associated device, controller,..).
Available configuration parameters (data type is 2 Byte DEC):
When Relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the device receives OFF command regardless from where it comes (push button, associated device, controller, etc.).
Available configuration parameters (data type is 2 Byte DEC):
Available configuration parameters (data type is 1 Byte DEC):
NOTE: Parameter is the same for turning OFF or ON.
Available configuration parameters (data type is 1 Byte DEC):
Set value means percentage, set value from 0 - 100 = 0 % - 100 %. Available configuration parameters (data type is 1 Byte DEC):
NOTE: If power changed is less than 1 W, the report is not sent (pushed), independent of percentage set.
Set value means time interval (0 – 32535) in seconds, when power report is sent. Available configuration parameters (data type is 2 Byte DEC):
Set value means the type of the device that is connected to the output. The device type can be normally open (NO) or normally close (NC). Available configuration parameters (data type is 1 Byte DEC):
Binary switch and binary sensor I2 and I3 widgets are visible in the UI.
Disabled Endpoint I2 and I3
Widgets are not visible in the UI, only the binary switch widget is.
Enabling I2 & I3 means that Endpoint (I2 & I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Available configuration parameters (data type is 1 Byte DEC):
Endpoint device type selection:
- notification sensor (1 - 6):
GENERIC_TYPE_SENSOR_NOTIFICATION,
SPECIFIC_TYPE_NOTIFICATION_SENSOR
- sensor binary (9):
GENERIC_TYPE_SENSOR_BINARY,
SPECIFIC_TYPE_NOT_USED
NOTE 1: After parameter change, first exclude device (without setting parameters to default value) then wait at least 30 s and then re-include the device!
NOTE 2: When the parameter is set to value 9 the notifications are sent to Home Security.
If the temperature sensor is connected to the device, the temperature sensor widget is shown automatically in UI (user interface).
If the measured temperature with an additional temperature measuring device is different from the one measured by the connected digital temperature sensor, the temperature can be compensated by this parameter.
Available configuration parameters (data type is 2 Byte DEC):
If digital temperature sensor is connected, device reports measured temperature on temperature change defined by this parameter.
Available configuration parameters (data type is 1 Byte DEC):
https://www.youtube.com/watch?v=U1LLKDQuQ48&feature=youtu.be
Details of the product above will be automatically included with your enquiry.